Rissy Plastics, LLC

Siphon Retrofit using the CueBox

A retrofit of two failed alternating siphons with two 4 inch diameter Flouts, one with 17 inches drawdown, the other with 22 inches. drawdown.
 
Location: Geneva, NY
Date: November 2008
Installer: Ribble Septic 
 

The original dual siphons had failed. After removing the chamber lid, the old siphons were cut out.

retrofits/ribblesetup.jpg
The old siphons were removed

New plumbing was connected to the old siphon vents and the old traps were filled with mortar. The new connections were made by foaming in the new pipe stubs with urethane foam in a can (Great Stuff) and then topping  off with hydraulic cement. New connections were usable within a hour. Solid concrete blocks secure the CueBox and form landing pads for the different drawdown Flouts.

retrofits/ribblesetup.jpg
New piping installed to connect Flout system

Total install time was less than 6 hours. A down turned inlet pipe stills the incoming flow from the pump chamber. A 1/4 hole under the elbow prevents back siphoning.

retrofits/ribblesetup.jpg
New system goes right to work

retrofits/QB.17.22.wtrline.jpg
Design of the Siphon Retrofit. Note two different drawdowns.

DOWNLOAD this file PDF

Back to Siphon Retrofits